is a 7-channel RS485 Modbus RTU interface board designed for NTC Thermistors
: The number of channels is fixed at seven. nt18b07 manual
Ensure the antenna is properly connected and away from metal surfaces.
DC 6-24V (Supports DC 9V, 12V, 15V, 24V). Operating Current: 8-15MA. Input Channels: 7 channels for B3950 10K NTC thermistors. Temperature Measurement Range: -20∘Cnegative 20 raised to the composed with power C +125∘Cpositive 125 raised to the composed with power C (using recommended NTC sensor). Accuracy: Communication Interface: RS485 (MODBUS RTU). Baud Rate: 9600 (Default), N, 8, 1.
Before operating the NT18B07, always prioritize safety to prevent accidental discharge or injury:
Used to calibrate sensors if they deviate from actual temperature. Auto-Report Toggle 0 (Disable) Set to 1-255 for automatic reporting intervals in seconds. Used to read or write the device's Modbus address. Example Commands Read CH1 Temperature : Send the hex string 01 03 00 00 00 01 84 0A Response interpretation : If the returned data is 01 03 02 01 2C B8 09 (hex) = 300 (decimal), which means Change Slave ID : Use function code (Write Single Register) to update register Change Baud Rate Use the side panel buttons: was pressed against
Supports 10K ohm negative temperature coefficient thermistors. -20°C to +125°C Based on standard waterproof B3950 external probes. Module Accuracy 1% Base Tolerance
A: This is almost always caused by using an . The module is calibrated for a B3950 10K 1% NTC. A different type of thermistor will produce non-linear and inaccurate readings. Please double-check your sensor's specifications.
: Connect to the RS485 Data- line of your USB-to-RS485 adapter or PLC master. 2. NTC Thermistor Input Terminals
: Supports slave ID modification to network up to 247 modules on a single RS485 bus. Note: Deploy an RS485 repeater if cascading more than 16 modules to preserve signal integrity. Module Dimensions : 60 mm × 37 mm × 14 mm. Ensure the antenna is properly connected and away
This is the most frequent issue when setting up Modbus devices. The root cause is often a configuration mismatch.
This guide provides an overview of the technical specifications, setup, and communication protocol for the NT18B07 based on available LC12S NT18B07 Manual Overview documentation. 1. Technical Specifications LC12S NT18B07 is designed for low power consumption and high reliability.
To pull raw live temperatures, query registers 0x0000 through 0x0006 . Register Address (Hex) Register Address (Dec) Data Description Output Representation 0x0000 Channel 1 (CH1) Temperature Signed Integer (e.g., 252 = 25.2°C) 0x0001 Channel 2 (CH2) Temperature Signed Integer (e.g., -105 = -10.5°C) 0x0002 Channel 3 (CH3) Temperature Signed Integer 0x0003 Channel 4 (CH4) Temperature Signed Integer 0x0004 Channel 5 (CH5) Temperature Signed Integer 0x0005 Channel 6 (CH6) Temperature Signed Integer 0x0006 Channel 7 (CH7) Temperature Signed Integer