Proper installation is crucial for the security and reliable operation of the V2000-C controller.
The manual emphasizes the following:
A: The access mode is determined by how you add the user. Using key 0 adds a user that requires both a card and a PIN (Card + PIN). Using key 2 adds a user that requires either a card or a PIN (Card or PIN).
| Feature | Specification | | :--- | :--- | | | 125kHz (EM) or 13.56MHz (Mifare) | | User Capacity | 1,000 – 10,000 users (varies by firmware) | | Output Relay | Dry contact (NO/NC/COM), 2A/30VDC | | Power Input | 12V DC ±10%, 1-2A | | Operating Temp | -20°C to +60°C | | Waterproof Rating | IP65 (outdoor keypad models) | V2000-c Rfid Access Control User Manual
The V2000-C RFID Access Control system provides a robust, standalone security solution for managing entry points using 125kHz EM cards or 4-digit PINs, accommodating up to 1,000 users. It features versatile, non-PC-based management for adding/deleting users and flexible wiring options for both fail-safe and fail-secure modes, suitable for small to medium-sized facilities.
The V2000-c supports three operational modes. Switch using [Master Code] + # + 19 [Mode] # .
Waterproof/Weather-resistant (often IP65 rated depending on the exact casing variant). Proper installation is crucial for the security and
V2000-c RFID Access Control User Manual: Comprehensive Programming and Installation Guide The V2000-c RFID Access Control Keypad Go to product viewer dialog for this item.
Connect the wire of the V2000-C directly to the Positive (+) terminal of the Magnetic Lock. Configuration B: Fail-Secure Lock (e.g., Electric Strike) An electric strike requires power only when unlocking.
Requires X cards (1-9) to be swiped in sequence to open the door. Using key 2 adds a user that requires
Normally Open Relay output. Used for Fail-Secure locks (e.g., Electric Dropbolts/Strikes that require power to unlock).
The V2000-C is a digital keyless entry system designed for standalone operation. It does not require a computer or network connection to function; all user data and programming are stored directly on the device's internal non-volatile memory. Key Specifications Supports up to 2,000 users. Access Modes: Card only, PIN only, or Card + PIN combined.